Model H1301 Recovery and Recycling System
Installation, Operation and Maintenance Manual
Revision-L September, 2019
Page 10 of 105
IV. System Installation (continued)
A. Machine Location
Position the machine on a clean, level surface and use wheel chocks to insure that
the machine will not roll if accidentally pushed, or roll from operational vibration.
Maintain a service area of at least 3-feet around all sides of the machine to allow for
proper air circulation.
The ports of the machine are ¼” x 45 SAE Male Flare fittings. Refrigeration service
hoses of the appropriate length may be used to connect to the ports of the machine.
ALWAYS LOCATE THE SYSTEM ON AN EVEN AND LEVEL SURFACE.
DO NOT INSTALL THE SYSTEM IN AN OUTDOOR ENVIRONMENT. The
system is designed for indoor locations with ambient temperature from 70 to 80 degrees F
(21.1 to 26.7C).
DO NOT LOCATE THE EQUIPMENT IN OR NEAR THE VICINITY OF
FLAMMABLE MATERIALS OR VAPORS.
DO NOT LOCATE THE SYSTEM NEAR DRIPPING, SPRAYING, OR
STANDING MOISTURE OR WATER. The system enclosure IS NOT NEMA rated.
Contact with moisture and water may result in electrical short circuits which may cause
health and system hazards.
ALWAYS LOCATE THE SYSTEM IN AN AREA THAT IS COOL, DRY, AND
AWAY FROM DIRECT SUNLIGHT.
ALWAYS ATTEMPT TO MAINTAIN A MINIMUM 3/16” INSIDE DIAMETER
PLUMBING CONNECTIONS TO THE PORTS OF THE MACHINE WITH A MINIMUM
OF BENDS, LOOPS, LOW SPOTS, OR SAGS.