IX. System Specifications
1. Recovery Performance Agent 1301 only
Recovery Efficiency: +98%
Nitrogen Removal Efficiency: 99.6% Min.
Internal Capacity: 80 lbs.
Maximum Input Pressure: 600 psig Standard (Input pressures up to 900 psi are available)
Process Rate: 1-2 lbs. / minute
2. Recycled Purity Agent 1301 only
Non-Volatile Residue: Max 0.01% by Volume
Acid Content: Max. 3.0 PPM by weight
Water Content: Max 20 PPM by Mass
Particulate Content: None Visible
Liquid Phase Purity: 99.6 mole %
Vapor Phase Purity: Less Than 1.5% by Volume
3. Filtration System
Acid Filter: 42 cubic inch
Moisture Filter: 84 cubic inch
Particulate Filter: 98% retention 1-micron liquid phase, 0.4-micron vapor phase
4. Nitrogen Separation System
Cold Venting
5. Factory Set Points: For 1301 Recovery (refer to the proper sections of the manual for 1211
settings and adjustments)
Temperature Controller Alarm #1: -55 F
Temperature Controller Alarm #2: -60 F
Pressure Controller Alarm #1: 50 psia
Pressure Controller Alarm #2: 20-25 psia
Cooling System Control Set Point: -63 F
Inlet Pressure Regulator: 250 psig
Nitrogen Supply Pressure Regulator: 80 to 140 psig
Inlet Pressure Switch: 90-100 psig
Inlet Vacuum Switch: -10 Hg
Process Tank Pressure Switch: Open 200 psig
Process Tank Pressure Switch: Close 150 psig
6. Standard Power Requirements (other single phase voltages at 50hZ are available)
Electrical: 208-230 VAC, single phase, 60 Hz, 9 kW Load
7. Miscellaneous
Warm Up Period: 20 minutes from power-up
Dimensions 38.75” Wide x 64” Deep x 70.25” Height
Weight: 1000 lbs.
8. Maximum AGENT Contamination Levels
Do Not Introduce AGENT into the equipment that is known to exceed the following levels:
Moisture in excess of 100 PPM
Oil in excess of 500 PPM
Acid in excess of 80 PPM
Particulates in excess of 80 PPM
Other Contaminates in excess of 0.5%
Nitrogen – No Limit