Model H1301 Recovery and Recycling System
Installation, Operation and Maintenance Manual
Revision-L September, 2019
Page 101 of 105
VIII. Trouble Shooting Guide
K. Liquid Pump Trouble Shooting (continued)
3. Pump will not operate during automatic processing but will operate when the
front panel switch is in the ON position:
a. PLC output fuse is blown. The fuse is located just below the PLC. Examine the
fuse and replace as required with same rated fuse.
b. Pump PLC wiring is disconnected. Ohm-out wiring and repair connection.
c. PLC output section is damaged. Consult factory.
4. Pump will operate during automatic processing but will not operate when the
front panel switch is in the ON position:
a. Pump switch wiring is disconnected. Ohm-out wiring and repair connection.