Loading...
Modem
Reference Manual for EL470 IP Satellite Modem
Command
MoInpPacketRate
Input packetrate Input packetrate
Location /Modem/Monitor/Modulation/Packets
Description
Readout of the estimated input packet rate expressed in packets per
second.
RMCP
Command
ipr Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ModulatorEntry
Command ntcDevsMod01MoInpPacketRate
OID 1.3.6.1.4.1.5835.3.1.3.1.72.1.1
Values GUI Unit
pps
Cmd Unit Factory Default (CU)
pps 0
Expert Range (CU)
-1e+38 .. 1e+38
Command
MoPacketRate
Estimated packetrate Estimated packetrate
Location /Modem/Monitor/Modulation/Packets
Description
Readout of the estimated packet rate in packets per second.
RMCP
Command
mpr Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ModulatorEntry
Command ntcDevsMod01MoPacketRate
OID 1.3.6.1.4.1.5835.3.1.3.1.79.1.1
Values GUI Unit
pps
Cmd Unit Factory Default (CU)
pps 0
Expert Range (CU)
-1e+38 .. 1e+38
Command
MoPacketCnt
Packet count Packet count
Location /Modem/Monitor/Modulation/Packets
Description
Readout of the monitored packet count. All baseband packets on the
modulator are counted.
RMCP
Command
mpc Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ModulatorEntry
Command ntcDevsMod01MoPacketCnt
OID 1.3.6.1.4.1.5835.3.1.3.1.78.1.1
Values GUI Unit
NA
Cmd Unit Factory Default (CU)
NA 0
Expert Range (CU)
0 .. 4294967295