9 Setting of NIBE FLM
VWDUW JXLGH 
WLPH EHWZHHQ GHIURVWV
PRQWKV EWZQ ILOWHU DODUPV
FRQWLQXRXV SXPS RS
)/0
KUV
This part of the start guide is only displayed if the altern-
ative is selected in a previous menu and the accessory is
installed.
time between defrosts
Setting range: 1 30 h
Default value: 10 h
months btwn filter alarms
Setting range: 1 12
Default value: 3
continuous pump op.: Select for continuous operation
of the circulation pump in NIBE FLM.
time between defrosts: Set the minimum time that
must pass between defrostings of the heat exchanger in
NIBE FLM.
When the exhaust air module is in operation the heat
exchanger is cooled so that ice builds up on it. When too
much ice builds up the heat transfer capacity of the heat
exchanger is reduced and defrosting is required. Defrost-
ing warms up the heat exchanger so that the ice melts
and runs off via the condensation hose.
months btwn filter alarms: Set how many months
should pass before the heat pump informs that it is time
to clean the filter in NIBE FLM.
Clean NIBE FLM's air filter regularly, how often depends
on the amount of dust in the ventilation air.
10 Setting the fan speed exhaust air
VWDUW JXLGH 
VSHHG
VSHHG
VSHHG
VSHHG
QRUPDO
IDQ VS H[KDXVW DLU
This part of the start guide is only displayed if the altern-
ative is selected in a previous menu and the accessory is
installed.
normal and speed 1-4
Setting range: 0 100 %
Set the speed for the five different selectable speeds for
the fan here.
Caution
Too low a value can damage the house in the
long term.
NIBE™ F1245Chapter 6 | Commissioning and adjusting32

Table of Contents

Other manuals for Nibe F1245

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1245 and is the answer not in the manual?

Nibe F1245 Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
Dimensions (HxWxD)1800 x 600 x 620 mm
Energy Efficiency Class Heating 35°CA++
Energy Efficiency Class Heating 55°CA++
Heating Capacity5-12 kW
COP Heating4.5
Integrated Hot Water Tank180 liters
Power Input Heating1.0 - 3.0 kW