14 Setting pool heating
VWDUW JXLGH 
DFWLYDWHG
VWDUW WHPS
VWRS WHPSHUDWXUH
r&
r&
SRRO
This part of the start guide is only displayed if the altern-
ative is selected in a previous menu and the accessory is
installed.
start temp
Setting range: 15.0 - 70.0 °C
Default value: 22.0 °C
stop temperature
Setting range: 15.0 - 70.0 °C
Default value: 24.0 °C
Select whether the pool control is to be activated and
within what temperatures (start and stop temperature)
pool heating must occur.
When the pool temperature drops below the set start
temperature and there is no hot water or heating require-
ment, F1245 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value
that is higher than the stop temperature.
15 Setting cooling function
VWDUW JXLGH 
FRROLQJ IORZ WHPS DW  r&
FRRODQW IORZ OLQH DW r&
WLPH EHWZ VZLWFK KHDWFRRO
FORVH PL[ YDOYHV LQ FRRO PRGH
PLQ WHPS FRROLQJ IORZ
FRROLQJ
r&
KUV
r&
r&
This part of the start guide is only displayed if the altern-
ative is selected in a previous menu. In addition, it requires
either the accessory to be installed or that F1245 has an
integrated function for cooling.
min. temp. cooling flow
Setting range: 5 - 50 °C
Default value: 10
cooling flow temp. at +20 °C
Setting range: 5 - 50 °C
Default value: 20
coolant flow line at +40°C
Setting range: 5 - 50 °C
Default value: 15
time betw. switch heat/cool
Setting range: 0 - 48 h
Default value: 2
heat at room under temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
cool at room over temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
You can use F1245 to cool the house during hot periods
of the year.
min. temp. cooling flow
Set the minimum temperature on the supply temperature
to the climate system during cooling operation. This
means that F1245 never calculates a temperature lower
than that set here.
NIBE™ F1245Chapter 6 | Commissioning and adjusting34