25 Setting max. flow line temp.
VWDUW JXLGH
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
r&
r&
r&
r&
PD[ IORZ OLQH WHPSHUDWXUH
climate system
Setting range: 15-80 °C
Default value: 60 °C
Set the maximum supply temperature for the climate
system here. If the installation has more than one climate
system, individual maximum flow temperatures can be
set for each system.
Caution
Underfloor heating systems are normally max
flow line temperature set between 35 and 45
°C.
Check the max floor temperature with your floor
supplier.
26 Setting the heat curve
VWDUW JXLGH
V\VWHP
RXWGRRU WHPS r&
IORZ WHPSHUDWXUH r&
At basic setting the climate system "heating curve" and
"temperature" (heating curve offset) must be changed.
Further information on how to set the heating curve can
be found on page 49.
Setting automatic heating controls with diagram
The diagrams are based on the dimensioned outdoor
temperature in the area and the dimensioned supply
temperature of the climate system. When these two val-
ues "meet", the heating control's curve slope can be
read. This is set under "heating curve“ in menu 1.9.1.
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
- 40 °C
UTETEMPERATUR
- 10
0
10
- 5
+ 5
30
40
50
60
70
°C
FRAMLEDNINGSTEMPERATUR
- 20 - 30
FÖRSKJUTNING
VÄRMEKURVA (-2)
VÄRMEKURVA
+($7,1* &859(
2876,'( 7(03(5$785(
6833/< 7(03(5$785(
2))6(7 +($7 &859(
30
40
50
60
70
°C
FRAMLEDNINGSTEMPERATUR
- 40 °C
UTETEMPERATUR
- 10
0
10
- 20 - 30
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
V