EasyManuals Logo

Nibe F1245 Installer Manual

Nibe F1245
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Caution
If the stop time is before the start time it means
that the period extends past midnight. Schedul-
ing always starts on the date that the start time
is set for.
Changes of temperature in accommodation take
time. For example, short time periods in combin-
ation with underfloor heating will not give a
noticeable difference in room temperature.
Menu 1.3.2 - cooling (accessory required)
Here you can schedule when cooling is permitted in the
accommodation for up to two different time periods per
day.
If two settings conflict with each other a red exclamation
mark is displayed at the end of the line.
6&+('8/,1* &22/,1* 
DFWLYDWHG
VFKHGXOH VFKHGXOH
DOO
PRQ
WXHV
ZH
WKXU
IUL
VDW
VXQ
 
RQ
7LPH SHULRG $GMXVWLQJ'D\
$FWLYDWHG
6FKHGXOH
&RQIOLFW
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated
here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a partic-
ular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: Whether or not cooling is permitted during
scheduling is set here.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in “all” and then
changing the desired days.
Caution
If the stop time is before the start time it means
that the period extends past midnight.
Scheduling always starts on the date that the
start time is set for.
Menu 1.3.3 - ventilation (accessory required)
Increases or decreases in the ventilation to the accommod-
ation can be scheduled here for up to two time periods
per day.
If two settings conflict with each other a red exclamation
mark is displayed at the end of the line.
DOO
PRQ
WXHV
ZH
WKXU
IUL
VDW
VXQ
DFWLYDWHG
VFKHGXOH VFKHGXOH
6&+('8/,1* 9(17,/$7,21 
 
VSHHG
7LPH SHULRG $GMXVWLQJ'D\
$FWLYDWHG
6FKHGXOH
&RQIOLFW
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated
here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a partic-
ular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: The desired fan speed is set here.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in “all” and then
changing the desired days.
NIBE™ F1245Chapter 8 | Control - Menus48

Table of Contents

Other manuals for Nibe F1245

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1245 and is the answer not in the manual?

Nibe F1245 Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
Dimensions (HxWxD)1800 x 600 x 620 mm
Energy Efficiency Class Heating 35°CA++
Energy Efficiency Class Heating 55°CA++
Heating Capacity5-12 kW
COP Heating4.5
Integrated Hot Water Tank180 liters
Power Input Heating1.0 - 3.0 kW

Related product manuals