Menu 2.3 - scheduling
What hot water comfort the heat pump is to work with
can be scheduled here for up to two different time peri-
ods per day.
Scheduling is activated/deactivated by ticking/unticking"ac-
tivated". Set times are not affected at deactivation.
If two settings conflict with each other a red exclamation
mark is displayed.
DOO
PRQ
WXHV
ZH
WKXU
IUL
VDW
VXQ
DFWLYDWHG
VFKHGXOH VFKHGXOH
6&+('8/,1* +27 :$7(5
QRUPDO
7LPH SHULRG $GMXVWLQJ'D\
$FWLYDWHG
6FKHGXOH
&RQIOLFW
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated
here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a partic-
ular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: Set the hot water comfort that is to apply
during scheduling here.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in “all” and then
changing the desired days.
Caution
If the stop time is before the start time it means
that the period extends past midnight.
Scheduling always starts on the date that the
start time is set for.
Menu 2.9 - advanced
Menu advanced has orange text and is intended for the
advanced user. This menu has several sub-menus.
Menu 2.9.1 - periodic increases
period
Setting range: 1 - 90 days
Default value: 14 days
start time
Setting range: 00:00 - 23:00
Default value: 00:00
To prevent bacterial growth in the water heater, the
compressor and the immersion heater can increase hot
water temperature at regular intervals.
The length of time between increases can be selected
here. The time can be set between 1 and 90 days. Factory
setting is 14 days. Untick "activated" to switch off the
function.
Menu 2.9.2 - hot water recirc. (accessory re-
quired)
operating time
Setting range: 1 - 60 min
Default value: 3 min
downtime
Setting range: 0 - 60 min
Default value: 12 min
Set the hot water circulation for up to three periods per
day here. During the set periods the hot water circulation
pump will run according to the settings above.
"operating time" decide how long the hot water circula-
tion pump must run per operating instance.
"downtime" decide how long the hot water circulation
pump must be stationary between operating instances.
NIBE™ F1245Chapter 8 | Control - Menus54