Menu 5.1.1 - hot water settings
start temp. economy / normal / lux
Setting range: 5 – 70 °C
Factory setting (°C):
luxurynormaleconomy5kW
474441Enamel
484542Copper
484542Stainless
luxurynormaleconomy6kW
464340Enamel
474441Copper
474441Stainless
luxurynormaleconomy8kW
454239Enamel
464340Copper
464340Stainless
luxurynormaleconomy10 kW
434037Enamel
444138Copper
444138Stainless
luxurynormaleconomy12 kW
423936Enamel
434037Copper
434037Stainless
stop temp. economy / normal / lux
Setting range: 5 – 70 °C
Factory setting (°C):
luxurynormaleconomy5kW
514845Enamel
524946Copper
524946Stainless
luxurynormaleconomy6kW
504744Enamel
514845Copper
514845Stainless
luxurynormaleconomy8kW
494643Enamel
504744Copper
504744Stainless
luxurynormaleconomy10 kW
474441Enamel
484542Copper
484542Stainless
luxurynormaleconomy12 kW
464340Enamel
474441Copper
474441Stainless
stop temp. per. increase
Setting range: 55 – 70 °C
Default value: 55 °C
Here you set the start and stop temperature of the hot
water for the different comfort options in menu 2.2 as
well as the stop temperature for periodic increase in menu
2.9.1.
Menu 5.1.2 - max flow line temperature
climate system
Setting range: 15-80 °C
Default value: 60 °C
Set the maximum supply temperature for the climate
system here. If the installation has more than one climate
system, individual maximum flow temperatures can be
set for each system.
61Chapter 8 | Control - MenusNIBE™ F1245