Operating procedure Display panel
(1) Make sure if the display panel shows
the furnace temperature and the
maximum setting temperature.
*This shows time (minutes) to start ring in the event
that you set timers.
Display Name of errors Reason
Countermeasure
Inability to raise the temperature
・ Thermocouples are forgotten to be set in kilns.
・ Install the thermocouples into the kiln.
・ The temperature setting is beyond the
heating ability of the kiln.
・ Set the suitable temperature.
・ The hot wire of the kiln is disconnected.
・ Stop ring, and change the hot wires after
cooling the inside of the kiln sufciently.
・ Door is opening during ring
・ Close the door paying close attention to the
heat of the kiln.
Disconnection of thermocouples
and electrical conductors
or
Detection of abnormal high
temperatures
・ Disconnection of the thermocouples or
electrical conductors
Loosening of connection
・ Abnormal high temperature inside the kiln
・ Repair and change the thermocouples or
electrical conductors by the condition of
heat insulation. Tighten the connection if
it is loose.
・ Please consult Nidec DriveTechnology
ceramics department
in the event that the display still shows F3
even if you try the above countermeasures
Reverse connection of
thermocouples
・ Polarity is reversely connected in connection
of thermocouples.
・ Shift the polarity of wire connection.
Abnormal temperature of
microcomputers
or
breakdown of temperature
censors
・ High abnormal temperature inside the
microcomputer
・ Breakdown of the temperature censor
・ Please consult Nidec DriveTechnology
ceramics department when it occurs.
7
Troubleshooting
1 About controller
When you want to make sure the content of the program you set
When you want to make sure if the ring mode is on or off
*The maximum setting temperature It
flashes on and off for 3 seconds every
20 seconds.
The kiln temperature
The maximum setting
temperature
Shows alternately
1 About controller
Error message : The error shows the problems of the kiln during ring.
Please correspond to the error message, push and cancel the error.
Error message
Conrmation if the microcomputer is in ring mode or not after starting ring
For example
shows ashing.
shows ashing.
Operating procedure Display panel
(1)
Push the key of the process you want
to conrm.
(2)
The display automatically turns back to show “In operation” in about 5 minutes.