7
Do not use extension cord
Do not connect several cords
into one plug.
Set kiln in a location which
you can ventilate well.
Ventilation is necessary for firing.
Please set kiln in a location which you
can ventilate well.
Please connect power cord into short
circuit breaker or cord for wiring.
2
1 Electric works
1 Electric works
*Allowable current of breaker size or wire depends on the circumstances of set-up location or
construction techniques.
Installation/Electric works
To Electricians
Please consider the specification of
kiln and circumstances of the set-up
location, and undertake construction
following all regulations.
DANGER
Ask professional
electrician to perform all
electrical work.
1.Connection to power supply
[2] Do not put objects
around the kiln.
2 Installation
1. Installation
(1) For indoor
(2) For outdoor
[3] Insulate.
[1]
Ventilate well.
[4] Use heat resistant
󳞜oors and walls.
[5] Set up kiln on a
󳞜at 󳞜oor.
Do not set in a location
which is susceptible to
direct sun light.
2 Installation
An odor may occur from the
pottery or kiln during 󳞛ring
since the temperature of the
kiln surface becomes high.
Please set up a fan for
air circulation and ventilate
the area well.
Please do not put objects
within 50cm around the kiln
for safety.
Please keep 50cm or more
from walls.
Please place rubber pads
under the legs of kiln for
protection to 󳞜oor.
Please place kiln on a floor
and near walls that are made
of heat resistant material such
as concrete or other such
material.
Please set up kiln on a solid 󳞜at 󳞜oor in a location that is not susceptible to rain or water.
DANGER
Do not set kiln in a location
that is susceptible to rain and
water.
Do not set under the 󳞛re-
alarm box or sprinkler.
WARNING
CAUTION
Do not set 󳞜uorescent light
on the top of kiln.
50 centimeter
50 centimeter
50 centimeter
Model
Capacity
Phase
Voltage Current Breaker Cable
kW V A AT mA mm
DUB-05 4.5 220 21 30
200
6
DUB-07 6.7 220 31 40 16
DUB-10 10.3
220 47 60 25
380 16 20 4
DUB-12 11.5 220 53 60 25
DUB-15 15.1
220 69 75 35
380 23 30 10