6
Model DUB-05 DUB-07 DUB-10 DUB-12
DU
B
-15
Outside dimension
W × D × H (mm)
890 × 810 × 730 890 × 810 × 955 1070 × 985 × 1070 1180 × 1070 × 855
1180 × 1070 × 1080
Inside dimension
W × D × H (mm)
φ 445 × 340 φ 445 × 570 φ 585 × 685 φ 715 × 455
φ 715 × 685
Weight 110kg 140kg 175kg 185kg
220kg
Electric capacity 4.5kW 6.7kW 10.3kW 11.5kW
15.1kW
Power voltage
1 φ 220V 21A 1 φ 220V 31A 1 φ 220V 47A
3 φ 380V 16A
1 φ 220V 53A
1 φ 220V 69A
3 φ 380V 23A
Firing Firing of controller
Heating elements Spiral heating elements
Attachments Gas venting tap 4 pcs
1
3 Operation
(1) Fix caster
Please operate the lever and lock the caster not to move the main body.
(2) Open and close door
Lift the door slowly.
Lower the door a little after setting stopper and release your hand.
Open the door
Hold the handle and bring the door up a little.
Pull stopper
Close the door slowly
Close the door
Please put 「Gas venting tap」
on when closing hole.
1 Kiln Diagram
2 Speci󳞛cation
3 Operation
Kiln Diagram/Speci󳞛cation/Attachments
1 Kiln Diagram
Gas venting hole
Thermocouples
Control panel
Power
Gas venting tap
Handle
Cover handle
2 Speci󳞛cations / Attachments
Caster
Stopper
Gas Damper