15 | Kato Engineering, Inc.
3.2 Electrical
CONTROL POWER (RECEIVER)
DC Voltage: 18 31V
DC Burden: 12.5W
Polarity Protected: No
RELAY OUTPUTS (RECEIVER)
Type: Form A x 3 Sealed
Contact Material: AgSnO
2
Operate Time: 10ms
Release Time: 10ms
Minimum Load: 100mA@5VDC
Maximum Load: 2A@250VAC Resistive (120000 Operations)
DIGITAL OUTPUTS (RECEIVER)
Type: Source/Sink x 3
Internal Source Resistance: Open Drain with internal pull up resistance of 10kΩ to V+
Maximum Sink Current: 250mA
3.3 Environmental
TEMPERATURE
Operating: -40 to +70°C
Storage: -40 to +85°C
SHOCK
TBD
VIBRATION
MIL-STD-167-1A
3.4 Certifications
UL RECOGNITION
UL recognized under standard 508, UL file number E233284.