33 | Kato Engineering, Inc.
6 Maintenance
No specific maintenance is required for the KRM2000
TM
system beyond what is required for the
exciter. During exciter maintenance, inspect all wiring between the receiver, transmitter, and
inductive loop antenna to verify proper connections are maintained and ensure they are free of
corrosion. If replacement of wiring is needed for the rotating transmitter connections, be sure to re-
apply a good quality, air drying insulating varnish.
For long term storage of the KRM2000
TM
, it is recommended that it be powered up once per year for
no less than one hour. This will ensure the life and help prevent the deterioration of the electrolytic
capacitors.
The following table defines the replacement/spare parts:
Table 4 Replacement/Spare Parts
GE PART NUMBER
(REFERENCY ONLY)
Power Loop Antenna for GE 6A6, LM6000, 6A8, 7A6, 6FA Kato Exciters
Power Loop Antenna for GE 9A5 Kato Exciters
Retrofit Kit for GE 9A4, 7A7
Power Loop Antenna for GE 9A4 Kato Exciters
Retrofit Kit for GE 6A6, LM6000
Loop Bracket for GE 6A6, LM6000
Loop Bracket + Loops & Resonator (7A6)
Loop Bracket + Loops & Resonator (9A4)
Loop Bracket + Loops & Resonator (6A8)
Sensing Filter Module for 9A5 Exciters
Sensing Filter Kit for 9A5 Exciters (includes 508-00247-20 sensing filter module)
Capacitor Snubber Module for 6A6/7A6/LM6000
-88 Snubber w/ Connection Leads 6A6/7A6/LM6000
Complete Snubber Kit for 6A6/7A6/LM6000 (2 pcs)
Bluetooth Communication Module