NE200&300 Quick Start Guide
60
Code
Description Setting range Default
Modify
Modbus
Address
control mode
2: Valid in Fault state of
terminal/ communication
control mode
3: Valid in both stop &
fault state of terminal/
communication control
mode
FE.03
Running
freq.(Hz)
(before
compensation)
0: No display
2 0F03H
1: Display at stop
2: Display at running
3: Display at stop &
running
FE.04
Running freq.
(Hz) (After
compensation)
0: No display
0 0F04H
1: Display at stop
2: Display at running
3: Display at stop &
running
FE.05
Reference
frequency (Hz
blinking)
0: No display
1 0F05H
1: Display at stop
2: Display at running
3: Display at stop &
running
FE.06
Output
current(A)
0: No display
2 0F06H
1: Display at stop
2: Display at running
3: Display at stop &
running
FE.07
Bus voltage (V)
0: No display
3 0F07H
1: Display at stop
2: Display at running
3: Display at stop &
running
FE.08
Output voltage
(V)
0: No display
0 0F08H
1: Display at stop
2: Display at running
3: Display at stop &
running