NE200&300 Quick Start Guide
55
Code
Description Setting range Default
Mod
ify
Modbus
Addres
s
Freq.7 selection potentiometer
4: Pulse input
Group FA: Wobble Frequency
Code
Description Setting range Default
Modify
Modbus
Address
FA.00
Wobble
amplitude
0.0~50.0% 0.0% ○ 0B00H
FA.01
Jitter frequency 0.0~50.0%(to FA.00) 0.0% ○ 0B01H
FA.02
Jitter Time 5
~
50ms 5ms ○ 0B02H
FA.03
Wobble freq. up
time
0.1
~
999.9s 5.0s ○ 0B03H
FA.04
Wobble freq.
down time
0.1
~
999.9s 5.0s ○ 0B04H
FA.05
Amplitude mode
0: Relative to the
central freq.
0 ○ 0B05H
1: Relative to Max.
frequency
Group Fb: Fixed Length
Code
Description Setting range Default
Modify
Modbus
Address
Fb.00
Preset length 0
~
65530 0 ○ 0C00H
Fb.01
Actual length 0
~
65530 0 * 0C01H
Fb.02
Pulses number
per unit
0.1
~
6553.0 100 ○ 0C02H
Group FC: Protection and Fault Parameters
Code
Description Setting range Default
Modify
Modbus
Address
FC.00
Motor overload 0: Disabled 1 × 0D00H