EasyManua.ls Logo

Nidec NE200 Series - Group FP Protection Parameters

Nidec NE200 Series
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NE200&300 Quick Start Guide
65
Code
Description
Setting range Default Modify
Modbus
Address
FF.10
Reserved Reserved Reserved
- 100AH
FF.11
Software
version
number of
control board
1.00~10.00 1 - 100BH
FF.12
Non-standard
version
number of
software
0~255 0 - 100CH
FF.13
Heat sink
temperature
-30.0
120.0°C 0.0°C - 100DH
IGBT
temperature
0.0
140.0°C 0.0°C - 100DH
FF.14
Flux
current
-200.0~200.0% * 100EH
FF.15
Torque
current
-200.0~200.0% * 100FH
FF.17
Accumulated
kilowatt-hours
Upper 16
bits
0~65535kWH 0kWH - 1011H
FF.18
Accumulated
kilowatt-hours
Low 16
bits
0~65535kWH 0kWH - 1012H
Group FP Protection Parameters
Code
Description
Setting range Default
Modify
Modbus
Address
FP.00
User
password
0~9999
0: No password
0 -
Others: password
protection
FP.01
Parameter
write-in
protection
0: All parameters are
allowed modifying
0 --
1: Only FP.01 and FP.03
can be modified

Related product manuals