NE200/300 Series Drive User Manual
126 Chapter 6 Parameter description
Setting the pulse quantity per circle of Encoder.
Note:
The operation status of motor will be abnormal if the pulse quantity of
encoder set is not correct while controlled by the vector sensor. Please
exchange the wiring of the A,B phases or adjust the value of F3.16 if the
operation status of motor is abnormal still while the pulse quantity set is
right.
F3.15 Motor and PG reduction
ratio
Range: 0.010~50.0001.000
Set this function code as 1 if the PG is on the axle of motor. Set this
function code as the real reduction gear ratio because there is a reduction
gear ratio between motor axle and PG while the PG is not installed on the
axel of motor.
F3.16 PG direction
Range: 0~1 0
0: Forward 1: Reverse
Don’t need to re-wiring while found the wiring sequence is not right, you
can set this function code as 1.
F3.17 ACC/DEC limit controlled by
PG
Range: 0~1 0
0: Limited
This means the real output frequency will limit the frequency after
ACC/DEC speed while controlled by PG option.
1: No limited
F3.18 SVC speed calculation filter Range: 0~15 5
F3.19 SVC mode Range: 0~1 0