EasyManua.ls Logo

Nidec NE200 - Page 145

Nidec NE200
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NE200/300 Series Drive User Manual
136 Chapter 6 Parameter description
F5.05 No-load current I0
【Depends on model】Range:
②
0.01~655.35A
③
0.1~999.9A
F5.06 Stator resistance
R1
【Depends on model】Range:
②
1~65535 mΩ
③
1~65535 mΩ (Drive rated power
≤22kW)
③
0.1~6553.5mΩ(Drive rated
power>22kW)
F5.07 Leakage Inductive
reactance X
【Depends on model】Range:
②
0.01~655.35mH
③
0.01~655.35mH(Drive rated
power≤22kW)
③
0.001~65.535mH(Drive rated
power>22kW)
F5.08 Rotor resistance R2
【Depends on model】Range:
②
1~65535mΩ
③
1~65535mΩ(Drive rated power≤22kW)
③
0.1~6553.5mΩ(Drive rated
power>22kW)
F5.09 Mutual Inductive
reactance Xm
【Depends on model】Range:
②
0.1~6553.5mH
③
0.1~6553.5mH(Drive rated
power≤22kW)
③
0.01~655.35mH(Drive rated
power>22kW)
The above parameters are instructed in the fig.6-12 as below:
1
U
1
R
1
jX
m
R
m
X
2
jX
s
R
2
0
I
1
I
2
I
Fig. 6-12 Asynchronous motor equivalent circuit
In the Fig.6-12, R1, Xl, R2, X2, Xm, and I0 represent resistance of stator,
leakage inductance of stator, resistance of rotor, leakage inductance of rotor,
mutual inductance and no-load current respectively. The setting of F5.07 is

Table of Contents