NE200/300 Series Drive User Manual
Chapter 6 Parameter description 137
the sum of leakage inductance of stator and leakage inductance of rotor.
After motor rated power (F5.02) is changed, the drive will automatically
change F5.03F5.09 to adapt to the rated motor power.
F5.10 Auto tune Range: 0~20
0: No operation
1: Static tuning, it is suitable to the situation as the motor is not easy to
disconnect from the load.
Action description: Set the function code to 1 and press RUN key for
confirmation, and then the drive will conduct static tuning.
2: Rotary tuning
To ensure the dynamic control performance of the drive, please select
rotary
tuning. During the rotary tuning, the motor must be disconnected with
the loads (i.e. no-load).
Action description:
Set the function code to 2 and press RUN key for confirmation, the
drive will conduct static rotary first, and then accelerate to 80% of
motor rated frequency according to the acceleration time set in F0.19,
holding this frequency for a while, and finally decelerate to zero speed
according to deceleration time set in F0.20.
F5.11 Synchronous motor stator
resistor Rs
Depends on model
Range
165535
165535mΩ (for drive
22kW)
0.16553.5mΩ (for drive>22kW)
F5.12 Synchronous motor D-axis
inductance Ld
Depends on modelRange
0.01~655.35mH
0.01~655.35mH (for drive≤30kW)
0.001~65.535mH(for drive>22kW)
F5.13 Synchronous motor Q-axis
inductance Lq
Depends on modelRange
0.01~655.35mH
0.01~655.35mH (for
drive
≤30kW)