NE200/300 Series Drive User Manual
88 Chapter 5 List of Parameters
Code
Description Setting range Default
Modify
Modbus
Address
FC.00
Motor overload
protection mode
0: Disabled
1 × 0D00H
1: Common motor
(with low speed
compensation)
2: Variable
frequency motor
(without low speed
compensation)
FC.01
Electro thermal
protection value
20
110% 100% 0D01H
FC.02
Overload
Pre-alarm
detection level
30.0
200.0% 160% 0D02H
FC.03
Overload
Pre-alarm
detection time
0.0
80.0s 60.0s 0D03H
FC.04
Current amplitude
limit
0:Invalid
2
0D04H
1: Acc./Dec. valid;
Constant speed
invalid
2: Valid all the time
FC.05
Current amplitude
limit level
Type G
80.0
200.0%
G:
160.0%
0D05H
Type P
60.0
150.0%
P:
120.0%
FC.06
Over voltage stall
function
0: Invalid
(Recommended if
braking resistor
mounted)
1 ×
0D06H
1: Valid for Acc/Dec.
2: Valid all the time
FC.07
Overvoltage point
for Acc./Dec.
suspend
110.0
150.0%
(Bus voltage)
380V:
140%
× 0D07H
220V:

Table of Contents