64Service Manual – SC5000 04 - Control System
2-078 M8 Option Pump Motor Stall
Description M8 wash pump motor overload.
Setting
Conditions
The power module has detected excessive current in the wash
pump, but less than short circuit amperage.
When Monitored
Always
Possible Causes Failing motor
Initial Action
Troubleshooting Steps
Replace the pump motor
2-081 EEPROM Fault
Description EEPROM checksum error
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action Reboot the machine. If the error doesn’t clear, replace the power module.
Troubleshooting Steps
2-082 PDO Timeout Fault
Description Did not receive PDO message from the main controller in the timeout period
Setting
Conditions
Same
When Monitored
Always
Possible Causes
This error likely won’t be reported by the Main Machine Controller, as it would
indicate a communication failure.
Initial Action
Troubleshooting Steps

Table of Contents

Other manuals for Nilfisk-Advance Advance SC5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Advance SC5000 and is the answer not in the manual?

Nilfisk-Advance Advance SC5000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelAdvance SC5000
CategoryScrubber
LanguageEnglish

Related product manuals