65Service Manual – SC5000 04 - Control System
2-083 CAN Bus Fault
Description Internal CAN bus error
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action Reboot the machine. If the error doesn’t clear, replace the power module.
Troubleshooting Steps
2-084 Internal Comm Timeout
Description Internal master did not receive slave controller message in timeout period
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action Reboot the machine. If the error doesn’t clear, replace the power module.
Troubleshooting Steps
2-086 Over Temp Cutback
Description Internal temperature exceeded cutback temperature - output current will be reduced
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action
Shut down the machine and let it cool. If the error persists, replace the power
module.
Troubleshooting Steps