Trouble Possible Causes Remedy
Small amount of solution or no solution
reaches the brush
The tank lter (optional) is clogged/dirty Clean the lter
The solution lter is clogged/dirty Clean
The solenoid valve (EV1) is faulty or the electrical
connection is open
Replace the solenoid valve or
repair the electrical connection
There is dust/debris in the tank or in the detergent hoses,
obstructing the solution ow
Clean the tank/hoses
There is an open in the control/solenoid fuse (F3) Replace
The solution reaches the brush also
when the machine is off
There is dirt or calcium deposit on the solenoid valve
gaskets (EV1)
Clean the solenoid valve inner
gaskets
The solenoid valve (EV1) is broken Replace the solenoid valve
Specications
Descriptions / Model
Advance
SC450 20B
Nilsk
SC450 53B
Solution tank capacity 10.5 US gal (40 liters)
Min/max solution ow 0.10÷0.42 gpm (0.4÷1.6 liters/min)

Table of Contents

Other manuals for Nilfisk-Advance SC450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SC450 and is the answer not in the manual?

Nilfisk-Advance SC450 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSC450
CategoryScrubber
LanguageEnglish

Related product manuals