Solution System 145Service Manual – SC6500
™
Solution Solenoid Valve
The Solution Solenoid Valve opens to allow solution
ow to the scrub brushes. Although the Solution
Solenoid Valve
gets PWM voltage from the A2
Control Board, it remains full-open when the
solution pump is switched on.
Solution Manifold (disc decks only)
The Solution Manifold distributes the solution
from the solution pump and solenoid valve to the
nozzles adjacent to the scrub brushes.
Accessory Pump
The Accessory Pump is included in the
optional Spray Wand Kit. The pump
mounts on the underside of the chassis,
Solution
Solenoid
Valve
Solution
Manifold
Accessory
Pump