1. Close the door and turn the machine off by pushing the “Power” button.
2. The drain valve will activate and empty the machine of water.
3. When draining stops and the display is off, open door and remove and clean the
strainers and set aside.
4. Unscrew the wash and rinse arms from their manifolds.
5. Verify the nozzles and arms are free from obstruction. If clogged, remove end-
caps, clean nozzles with a brush, and flush with fresh water.
OPERATIONAL
INSPECTION
SHUTDOWN &
CLEANING
OPERATING INSTRUCTIONS
OPERATION
Based on use, the strainers might become clogged with soil and debris as the
workday progresses. Operators should regularly inspect the strainers to ensure they
have not become clogged. Clogged strainers will reduce the washing capability of
the machine. Instruct operators to clean out the strainers at regular intervals or as
required by workload.