EasyManua.ls Logo

nord NORDAC PRO SK 511E Series - Page 63

nord NORDAC PRO SK 511E Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Assembly and installation
BU 0505 EN-3021 63
Terminal block X5 Digital In
Relevance
SK 540E SK 545E
Terminals X5:
21
22
23
24
39
38
42
40
DIN1 DIN2 DIN3 DIN4 TF- TF+ VO 15V GND/0V
Designation
Terminal Function
[factory setting]
Data Description / wiring suggestion Parameter
21 Digital input 1
[ON right]
7.5...30V, R
i
=6.1k
Not suitable for thermistor
evaluation.
HTL encoders can only be
connected to DIN2 and
DIN4
Limiting frequency:
max. 10 kHz
Each digital input has a reaction time of
≤ 5ms.
Connection with internal 15V:
21
22
23
24
39
38
42
40
motor - PTC
15V
Connection with external 7.5-30V:
21
22
23
24
39
38
42
40
motor - PTC
GND / 0V
7.5 … 30V
P420 [-01]
22 Digital input 2
[ON left]
P420 [-02]
23 Digital input 3
[parameter set bit0]
P420 [-03]
24 Digital input 4
[Fixed frequency 1,
P429]
P420 [-04]
39 Thermistor input -
Potential isolated
thermistor input, which
cannot be disabled, for
monitoring the motor
temperature with a PTC
38 Thermistor input +
42 15V supply voltage
output
15V ± 20%
max. 150 mA (output)
short-circuit resistant
Supply voltage provided by the
frequency inverter for connection to the
digital inputs or the supply of a 10-30V
encoder.
40 Reference potential
for digital signals
0V digital Reference potential

Table of Contents