SK 54xEUsers Manual for Frequency Inverters
64 BU 0505 EN-3021
Relevance
SK 540E SK 545E SK 510E SK 511E SK 515E SK 520E SK 530E SK 535E
Terminals X5:
21
22
23
24
25 / 39
41 / 38
44*
40
* Terminal 44:
up to Size 4: VI
Size 5 and
above: VO
DIN1 DIN2 DIN3 DIN4 DIN5 / TF- VO 5V / TF+ V…24V GND/0V
Designation
Terminal Function
[factory setting]
Data Description / wiring suggestion Parameter
21 Digital input 1
[ON right]
7.5…30V, R
i
=6.1k
Not suitable for thermistor
evaluation.
HTL encoders can only be
connected to DIN2 and
DIN4
Limiting frequency:
max. 10 kHz
Each digital input has a reaction time of
≤ 5ms.
Size 1 to 4:
21
22
23
24
39
38
44
40
motor - PTC
GND / 0V
18 … 30V
Above size 5:
21
22
23
24
25
41
44
40
GND / 0V
18 … 30V
P420 [-01]
22 Digital input 2
[ON left]
P420 [-02]
23 Digital input 3
[parameter set bit0]
P420 [-03]
24 Digital input 4
[Fixed frequency 1,
P429]
P420 [-04]
25 Digital input 5
[no function]
available: above size 5
P420 [-05]
39 Thermistor input -
available: Size 1 - 4
Potential isolated
thermistor input, which
cannot be disabled, for
monitoring the motor
temperature with a PTC
38 Thermistor input +
41 5V supply voltage
output
available: size 5 and above
5V ± 10%
max. 250 mA (output) not
short-circuit resistant
44
Size 1 to Size 4
VI 24V supply
voltage input
18…30V
min. 800mA (input)
Voltage supply for the FI control unit. Is
essential for the function of the
frequency inverter.
Size 5 and above
VO 24V supply
voltage output
24V ± 25%
max. 200 mA (output)
short circuit resistant
Supply voltage provided by the
frequency inverter for connection to the
digital inputs or for the supply of a 10-
30V encoder.
The 24V control voltage is generated by
the FI, however it can also be supplied
via the terminals X12:44/40 (Size 8 and
above: X15:44/40). Supply via terminal
X5:44 is not possible.
40 Reference potential
for digital signals
0V digital Reference potential
Pos: 84 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Elektr ischer Anschluss/S K 500E/2.10.5 Elektri scher Anschluss Steuer teil- Klemmenblock X6 Encoder [ SK 54xE] @ 2\mod_135547533680 7_388.docx @ 52162 @ 5 @ 1

Table of Contents