E 1-6
Series 3000V lnput/Output
Board
2. lnput/Output
Connections
@ontd.)
Fig.
E 1-5 Enhanced
l/O Board
Connections
Table E
1-2 Enhanced
l/O Board
Connections
X1 lnputs
X2 Outputs
(See
Note A)
Function
Controlled
Remotely
Terminals
lndication
Shown
Remotely Terminals
Turn standby
feature
on
(See
Note B)
1,2
Power on/off
status
(normally
closed when
system is
powered)
1,2
Turn
heaters
on
(See
Note B)
7,8
Pump on/off
status
(normally
closed when
pump
is
on)
3,4
Enter
standby if
guns
are not fired within
a
specified
period
of time
(See
Note
C)
13, 14
Standby on/off
status
(normally
closed when
system is in
standby)
5,6
Disable
hose and
gun
one
(See
Note
B)
9,
'10
Warning
condition
(normally
closed when
no
warning condition
exists)
7,8
Disable
hose
and
gun
two
(See
Note B)
3,4
Disable
hose and
gun
three
(See
Note
B)
15,16
Disable
hose and
gun
four
(See
Note B)
11, 12
Disable hose
and
gun
five
(See
Note B)
5,6
Disable
hose
and
gun
six
(See
Note B)
17,
18
NOTE
A:
B:
Output
contacts
are
rated
for 250 VAC,
2 A maximum.
This input is
activated
by supplying
between 12-24VDC
across the designated
terminals of the l/O
board. lf the
voltage
is removed,
the input is
deactivated. lf
a zone is enabled
through the l/O board,
the READY light will not
turn on until
that
zone
is within
5" F
(-15"
C)
of its setpoint
temperature.
This feature
is activated
by
programming
Feature
30,
Auto
Standby Timeout. A
gun
is usually
signaled to fire by
a
timer or
programmable
logic controller
(PLC).
lf
a time value other than zero
(0)
is entered in Feature
30
(Auto
Standby Timeout),
the unit
will automatically
enter the standby
mode
if
a
gun
is not fired
during the specified time
period.
Refer to Timeout
Features in
this section.
U6
1
U9
U7
U5
C
!o
l<2
K3
x2
K5
a
TURN HEATERS
ON
ENTER
STANDBY
GUNS NOT FIRED
lFl
TURN STANDBY
ON
DISABLE HOSE/GUN
TWO
DISABLE HOSBGUN
FIVE
DISABLE HOSE/GUN1
THREE
DISABLE
HOSE/GUN1
stx
1
DISABLE HOSE/GUN
,10
DISABLE HOSE/GUN
FOU
STANDBY ON/OFF
6
1
POWER
ON/OFF STATUS
PUMP ON/OFF STATUS
WARNING CON
7
I
4
El EN-02-[3V-rO]-3
41-3000v
lssued 5/00
@
2000 Nordson Corporation
All rights reserved

Table of Contents

Other manuals for Nordson 3100V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson 3100V Series and is the answer not in the manual?

Nordson 3100V Series Specifications

General IconGeneral
BrandNordson
Model3100V Series
CategoryMelting Machines
LanguageEnglish

Related product manuals