14
MEG® II Airless Spray Guns with 10 ft Cable
© 2021 Nordson Corporation
1602990-12
Gun Module Replacement
WARNING:
performing the following procedure. Failure to do so could result in personal injury.
NOTE: The gun module can be replaced without removing the gun from the spray
machine.
See .
Have the following ready:
• module service kit
•
The module service kit is shipped assembled. It consists of the:
• gun module • spacer
• gun module O-ring • armature assembly
• seat • nozzle nut
• seat O-rings • seat retainer nut
NOTE: Inspect all O-rings and replace any that are damaged. Lubricate all O-rings with
petroleum jelly before assembly. The soft goods service kit listed in Parts includes all
O-rings used in the MEG gun, or they can be ordered separately.
See Figure 5.
1. If used, remove the CleanSleeve cover from the spray gun.
2.
3.
4.
5.
CAUTION: Make sure you install the new gun module so that the two pins in the gun
gun module.
6.
7. Tighten the set screw on the gun module nut.
8.
9. Insert the nozzle into the nozzle nut. Thread the nozzle nut onto the spray gun and
overtighten the nut.
NOTE:
the wrench on extended tip guns. Do not overtighten the nut.
10.
procedure as detailed in the CleanSleeve Cover