297-1001-330 Standard 11.04 June 1998
Section
CONTROL
Description
Input/output controller fault
Definition
The unit failure rate of input/output controllers.
Measurement list
IOCFLT uses measurement IOC IOCFLT.
Normalizer
IOCFLT is normalized per working IOC per unit time.
Diagnostics
Verify OM group IOC (IOCFLT). Diagnose error conditions at the IOC and
relevant levels of the MAP. Look for detailed information in IOD subsystem
logs IOD104, IOD116, IOD118, IOD119, IOD124, IOD125, IOD126,
IOD127, IOD109, IOD113, and IOD129.
6-16 SPMS MTCEPERF index descriptions 6-166-16