BILLPERF
Description
Metering performance
Definition
The summary of the error performance during central control (CC) metering.
Measurement list
METERERR uses the sum of measurements DTCALLP, DTXPM, DTFEAT,
TIMEST0, DURERR, COUNTERR, MTRBKERR, MTRAUDER,
RECYCFND, RECYCCLR, THQOVFL, THQERR, and TODXPMFL of
OM group MTRPERF.
Normalizer
METERPF is normalized per metered calls obtained from OM group
MTRUSG registers LNXPMM1, LNXPMM2, TKXPMM1, TKXPMM2,
LNCCM1, LNCCM2, TKCCM1 and TKCCM2.
Diagnostics
Check OM group MTRPERF and logs MTR100 through MTR142.
6-108 SPMS MTCEPERF index descriptions 6-1086-108
Basic index METERPF