297-1001-330 Standard 11.04 June 1998
Section
TERMNALS
Description
System load module (SLM) fault
Definition
The number of faults detected in the SLM card.
Measurement list
SLMFAULT uses measurement SLMFLT of OM group SLM.
Normalizer
SLMFAULT is normalized per working SLM unit per unit time.
Diagnostics
Check OM group SLM, register SLMFAULT. Check logs SLM403 and
SLM404 for more details.
6-200 SPMS MTCEPERF index descriptions 6-2006-200
Basic index SLMFAULT