297-1001-330 Standard 11.04 June 1998
Section
CPRES
Description
Call process letter overflow
Definition
The overflow rate of call process letters.
DMS-100G Switch does not impact this basic index due to the different call
processing infrastructure.
Measurement list
CPLOVFL uses the sum of CP measurements CPLOOVFL and
CPLPOVFL. CPLPOVFL indicates a serious shortage, but CPLOOVFL
does not.
Normalizer
CPLOVFL is normalized by the sum of CP measurements CPLSZ (with
extension register CPLSZ2), CPLOOVFL, and CPLPOVFL.
Diagnostics
Check CC real-time occupancy or the provisioning of call-processing letters.
Verify OM group CP (CPLOOVFL, CPLPOVFL) and associated logs
OM2200 MINOR ALM and OM2200 MAJOR ALM. Check OM group
CP2 for overflow.
7-8 SPMS PROVRES index descriptions 7-87-8
Basic index CPLOVFL