297-1001-330 Standard 11.04 June 1998
Section
LINKPERF
Description
Input/output controller link error
Definition
The rate of occurrence of errors on links between the IOCs and I/O devices
or device controllers.
Measurement list
IOCLNKER uses measurement IOC IOCLKERR.
Normalizer
IOCLNKER is normalized per working IOC P-side link per unit time.
Diagnostics
Verify OM group IOC (IOCLKERR). Further information is available from
IOD subsystem logs IOD117 and IOD129. Diagnose IOC P-side port
problems at the IOC and CARD levels of the MAP.
6-116 SPMS MTCEPERF index descriptions 6-1166-116
Basic index IOCLNKER