DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
Section
TERMNALS
Description
Line outage
Definition
The unavailability of individual line circuits.
DMS-100G Switch does not contribute to or provide an equivalent of OM
group SYSPERF
Measurement list
LINEOUT uses measurement SYSPERF LINCCTBU. This excludes outage
in the LM-busy state; for example, because of PM or drawer outage.
Normalizer
LINEOUT is normalized per working line per unit time.
Diagnostics
Verify OM group SYSPERF (LINCCTBU). Review line maintenance
procedures to ensure early recognition of faults and minimal line outage.
Reference focused maintenance if available.
6-205 SPMS MTCEPERF index descriptions 6-2056-205