DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
Section
LINKPERF
Description
Network module junctor system outage
Definition
The unavailability of network module junctor facing ports. Each port carries
31 speech channels.
Measurement list
NMJCTSOU uses the sum of NMC measurement NMJRSBU.
Normalizer
NMJCTSOU is normalized per network module port per unit time. The
number of network module ports is calculated as the number of working
network modules, multiplied by two planes, multiplied by 64 ports.
Diagnostics
Verify OM group NMC (NBMJRSBU). Check the availability of the
network module junctor facing ports. Junctor ports can be diagnosed from
JCTRS level of the MAP. Further information may be obtained from logs
NETM122, NETM123, and NETM140.
6-133 SPMS MTCEPERF index descriptions 6-1336-133
Basic index NMJCTSOU