DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
2-1
Startup procedures
SPMS operates automatically when SPMS option NTX738AB is present in
the switch. The customer need only set the day for the start of the report
month in the table OFCENG (office parameters).
Setting the day of the month
Access the CI level of the MAP display by typing
>QUIT ALL
and pressing the Enter key.
Access table OFCENG by typing
>TABLE OFCENG
and pressing the Enter key.
Note: If the system responds with a request for a password, contact your
Nortel representative immediately.
MAP response:
TABLE: OFCENG
Position on the required tuple by typing
>POS SPMS_START_OF_MONTH
and pressing the Enter key.
Enter the day for the start of the report month.
Note: The acceptable range of values for START_OF_MONTH is 1 to 28.
The default value is 1.
SPMS automatic report setup
SPMS reports can be automatically generated at any time you specify when
SPMS option NTX738AB is present on the switch and your load is BCS30
or later. The operating company must add the SPMS report to the list of

Table of Contents

Other manuals for Nortel DMS-100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel DMS-100 Series and is the answer not in the manual?

Nortel DMS-100 Series Specifications

General IconGeneral
BrandNortel
ModelDMS-100 Series
CategoryControl Unit
LanguageEnglish

Related product manuals