Page #145 background image
DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
Section
CONTROL
Description
Computing module fault
Definition
The failure rate of the computing module and the associated memory
hardware.
Measurement list
CMFLT uses the sum of CM measurements CMCPUFLT, CMMEMFLT,
CMSSCFLT, CMMCSBSY, CMRMEMFL, CMRCPUFL, and
CMRLNKFL.
Normalizer
CMFLT is normalized per unit time.
Diagnostics
Check logs CM125, CM112, CM104, and CM122.
Basic index CMFLT
for SuperNode CONTROL components
6-31 SPMS MTCEPERF index descriptions 6-316-31