UDS-4N
Extinguishing unit
Question and Answer IconNeed help?

Do you have a question about the Notifier Honeywell UDS-4N and is the answer not in the manual?

Notifier Honeywell UDS-4N Specifications

General IconGeneral
BrandNotifier
ModelHoneywell UDS-4N
CategoryControl Systems
LanguageEnglish

Summary

General Description

User Interface

Details the user interface elements, including LEDs and touch display for system status.

Electrical Characteristics

Dimensions and Specifications

Provides physical dimensions, weight, degree of protection, and environmental conditions for the UDS-4N.

Terminal Blocks Overview

Details the CN1, CNL, CNSE, CNBAT, CNO, CNLC, and CNIN terminal blocks and their pinouts.

Input and Output Descriptions

Explains the functionality of unit inputs and outputs, including resistance drift control and fault signalling.

Analogue Panel Interface

Analogue Module Functionality

Explains the use of output and input modules for analogue panel communication and signalling.

Front Panel Controls and Signals

Control Key Functions

Describes the functions of the panel buttons like End Flooding, Exclusion, Buzzer Mute, and Reset.

LED Indicators and Alerts

Explains the meaning and colour of each LED indicator on the front panel.

Dip-Switch and JDSPE Settings

Describes the function of dip-switches and the JDSPE jumper for unit configuration.

Operating Conditions

Programming, Testing, and Utilities

Programming Menu: Loop Setting

Configuration of loop addresses for incorporated modules and enabling/disabling of modules.

Programming Menu: Password Management

Details setting and default passwords for different access levels on the UDS-4N.

Configuration Menu: General Settings

Covers shutdown, flow control, and delay configurations like activation time and reset delay.

Configuration Menu: Power Off Settings

Configures trigger time for 'Power Off' output and flow control settings.

Configuration Menu: Delay Settings

Sets automatic discharge, manual discharge, and reset delay times for the unit.

Configuration Menu: Activation Mode

Configures the unit to operate in Automatic or Manual Only mode.

Utility Menu: Date and Time Settings

Allows setting the current date and time for the UDS-4N unit.

Utility Menu: Historical Archive Management

Details viewing, filtering, clearing, and saving the event history log.

Utility Menu: Firmware Update

Procedure for upgrading the UDS-4N firmware using a USB stick.

Utility Menu: Touch Screen Calibration

Guides the user through calibrating the touch screen for accurate input.

Test Menu Functions

Allows testing of LEDs, LCD display, and buzzer for operational verification.

Important Operational Information

Installation and Connection Procedures

Panel Wall Mounting Instructions

Provides guidelines for safely and correctly mounting the UDS-4N panel on a wall.

Cable and Network Connection

Specifies guidelines for connecting alarm devices, power supply, and network cables to the unit.

Internal Power and Battery Connection

Explains the internal battery charger and connection of the 12V batteries for mains failure backup.

Wiring Diagrams for Terminal Blocks

Illustrates wiring for CNL, CNIN, CNLC, and CN0 terminal blocks and specific output connection diagrams.

Commissioning Procedures

Functionality Standards and Additional Features

Compulsory Functions Overview

Lists the compulsory functions required by EN 12094-1 for the extinguishing control device.

Optional Functions Overview

Details optional functions and their requirements according to EN 12094-1 standards.

Additional Functionality Details

Explains programming options for analogue units, switch-off time, pressure/flow inputs, and exclusions.