Edition 02 to 12/2013
3.3
SERVICE MANUAL
3.1 ACCESS
To access the pouring group, just open the
door.
The service engineer needing to intervene on
the system will need to:
1 Switch off the machine.
2 Remove the ground drawer.
3 Turn the key anticlockwise.
4 Open the front panel.
The pouring group is in the middle.
3.2 POURING GROUP REMOVAL
The service engineer will have to:
1 Remove the phillips screw holding the
motor protection guard in place.
2 Using a 10 mm socket wrench, loose the
right-hand screw.
3 Remove the motor cover.
4 Remove the guard protecting the pouring
group plug.
5 Remove the top piston taking off the clip
(A) and sliding it out from below.
3
2
1
4
Fig. 3
1
2
3
Fig. 4
5
4
A
Fig. 5

Table of Contents