EasyManua.ls Logo

Nuova Simonelli TALENTO - Group Motor Removal; Heating Element and Probe Removal

Nuova Simonelli TALENTO
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Edition 02 to 12/2013
3.5
SERVICE MANUAL
3.3 GROUP MOTOR REMOVAL
The service engineer now needs to:
1 Remove the two screws at the top, under
the upper motor bracket with the 10 mm
wrench.
2 Slide out the motor.
3 Remove the faston connections.
This operation can be carried out with the
group fitted to the machine and following the
same procedure.
3.4 HEATING ELEMENT AND
PROBE REMOVAL
To remove the heating element.
1 Loosen the 2 mm allen screw (A) and
slide out the heating element.
2 Free the wire from the clamps and then
use an extractor to disconnect the two
pins from the wiring connector.
2
1
3
Fig. 10
A
1
Fig. 11
2
Fig. 12