Edition 02 to 12/2013
9.9
SERVICE MANUAL
Fig. 26
Fig. 27
Fig. 28
A The air compressor 24V is in the right side,
it injects air in the steam line coming to the
cappuccino maker.
B The T fitting is only in the machine equipped
by the EASYCREAM wand.
C The solenoid valve and the regulator for cold
milk are in the top left side.
9.2.4 WASHING AND AIR SOLENOID
VALVE FOR HOT MILK
To access the washing and air solenoids valve for
hot milk, the engineer needs to:
1 Switched off the machine.
2 Remove the grounds drawer.
3 Turn the key anticlockwise.
4 Open the front panel.
The air solenoid valve for hot milk is connected to:
A
Blue silicon pipe coming from air compressor
B Air adjustment screw
C Y fitting of steam pipe for cappuccino maker
Fig. 25