42640901TH Rev.1 33 /
Oki Data CONFIDENTIAL
2.3.16 Sensor Plate (Inlet)
(1) Remove the upper cover (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove the face up stacker assy (see 2.3.7).
(4) Remove the lower base unit (see 2.3.4).
(5) Unlock the latch at the left side of the paper guide (R) 1 and remove the paper guide (R) 1.
(6) Press the clamps of three sensor plates (inlet and paper) 2, and remove them by pressing them
upward from the bottom.
2
2
2
1
Sensor plate (inlet)
Sensor plate (paper)
Sensor plate (inlet)