- 116 -
5. Management / Setting the Printer
6
Click [Submit].
The new settings take effect when the network function of this machine restarts.
If you were unable to set up IPSec due to the inconsistency of the parameters that were specified, you cannot access
the Web page. In such a case, disable the IPSec from the operator panel of this machine or initialize the network
settings.
Proceed to "Setting a Computer".
Setting a Computer
Set IPSec to a computer.
Follow the procedure below, and be sure to perform all the steps in order.
Creating an IP Security Policy
1
Click [Start], and then select [Control Panel] > [System and Security] >
[Administrative Tools].
2
Double-click [Local Security Policy].
3
Click [IP Security Policies on Local Computer] in the [Local Security Policy]
window.
4
Select [Create IP Security Policy] from the [Action] menu.
5
Click [Next] in [IP Security Policy Wizard].
6
Enter [Name] and [Description], and then click [Next].
7
Clear the [Activate the default response rule (earlier versions of Windows
only)] check box, and then click [Next].
8
Select the [Edit Properties] check box, and then click [Finish].
Setting Key Exchange
1
Select the [General] tab in the New IP Security Policy Properties window.
2
Click [Settings].
3
Enter a value (minutes) in [Authenticate and generate a new key after every] in
the [Key Exchange Settings] window.
Specify the same value as [Lifetime] in the "Phase1 Proposal" setting in "Setting This Machine". Enter a value
in minutes in this step even if [Lifetime] is specified in seconds.
4
Click [Methods].
5
Click [Add] in the [Key Exchange Security Methods] window.
6
Specify [Integrity algorithm], [Encryption algorithm], and [Diffie-Hellman
group].
Select the same value specified in [IKE Encryption Algorithm], [IKE Hush Algorithm], and [Diffie-Hellman
group] in the "Phase1 Proposal" setting in "Setting This Machine".
7
Click [OK].
8
Select [OK] in the [Key Exchange Security Methods] window.
9
Click [OK] in the [Key Exchange Settings] window.
Setting an IP Filter
1
Select the [Rules] tab in the IP security policy properties window.
2
Click [Add].
3
Click [Next] in [Security Rule Wizard].
4
Select [This rule does not specify a tunnel] on the [Tunnel Endpoint] screen,
and then click [Next].
5
Select [All Network Connections] on the [Network Type] screen, and then click
[Next].
6
Click [Add] on the [IP Filter List] screen.