MAINTENANCE
13. Disconnect four connectors [1] and
remove four screws [2], and remove
the DC power supply assy [3].
7.3.12 High voltage unit (HV)
1. Remove the right cover.
See P.76
2. Disconnect three connectors [1] and
remove four screws [2], and remove
the high voltage unit [3].
Precautions for reinstallation of the
high voltage unit
Make sure that the high voltage unit
fits into the tab [1] at the location
shown on the left.
During the reinstallation procedure,
make sure that the high voltage ter-
minal is not deformed or left loose.
A0HFF2C500DA
[1]
[2]
[3]
A034F2C019DA
[1] [2]
[2]
[3]
A034F2C020DA
[1]
6.3.12 High voltage unit (HV)
7.3.13 Transfer roller unit
1. Remove the imaging cartridge.
See P.71
2. Press and pull the levers [1] at both
sides forward to remove the transfer
roller unit [2].
NOTE
Use care not to lose the two springs
of the transfer roller unit. They can
easily come off.
3. To reinstall, reverse the order of removal.
NOTE
When the transfer roller unit is replaced with a new one, it is necessary to reset the
maintenance counter.
See P.129
Make calibration after replacing the transfer roller unit.
See P.105
A034F2C021DA
[1]
[2]
6.3.13 Transfer roller unit