Pellematic
34
RelayFaultSignalStatus(OnOff)RelayFaultSignal
MotorRA1
Status(OnOff)MotorRA1
MotorRES1Status(OnOff)MotorRES1
MotorBurnerAuger
Status(OnOff)MotorBurnerAuger
11.3FullPower
FullPowerisinthemenuPellematic
InthemenuitemFullPoweryoucanadjustthefuel
feed.
Fuelcorrection:
Theburneraugerruntimeiscalculatedautomatically
bythePLCdependingontheratedpowerandthe
boilersetpointtemperature.Theburnermotoris
controlledaccordingly.Youcanreduceorincrease
thevaluecalculatedbythePLC10stepsupordown.
11.4De-ashingsystem
De-ashingsystemisinthemenuPellematic.
ThemenuitemDe-ashingsystemisavailableonly
whenDe-ashingsystemisconnected.Theactivation
isonlypossilbeafterenteringtheCodeforservice
tecnicians.Thede-ashingsystemandtheburner
platecleaningworkparallel.
•Minruntimeoftheboileruntilnextde-ashing
procedure.Valueadjustable
•AshdeliverytimeIstheruntimeoftheashauger.
Valueadjustable.