11.7SuctionSystem
SuctionSystemisinthePellematicmenu.
SuctionSystemhasthefollowingmenuitems:
•Cleaning/Filling
•FrequenceRAMotor
•PauseRAMotor
•Suctioninterval
Adjustthesuctionsystemaccordingtothedemandsofyourheatingsystem.
Cleaning/FillingThevaluetobesetisthetime(fullhour)atwhichtheboilercleaningsequenceisto
beperformed.
Thecleaningoftheboilerisperformedatthesametime.
InCleaning2asecondcleaning/llingsequencecanbeset.Thevaluetobeset
isthetime(fullhour)atwhichtheadditonalboilercleaningsequenceisperformed.
Example:20h=additionalboilercleaningsequenceperformedat20:00.Onvacuum
systemsthehopperisalsolledatthesametime,regardlessofwhetheritisempty
ornot.
FrequRAMotor
Frequencyforstorageroomsuctionsystemsinpulsemode,onlyforvacuum
systems.
PauseRAMotor
Pausetimeforstorageroomextractormotor-suctionsysteminpulsemode.If
pausetime=0thennopulsemode.
SuctionIntervalRuntimeofburneraugeruntilnextSuctionInterval.
Thehopperislledatthistimeregardlessofwhetheritisemptyornot.
OperatingmanualPelletronicTouch