Descriptionoftheheatingcontrollermodule
45
17Descriptionoftheheatingcontrollermodule
Theheatingcontrollerisdesignedtocontroltheheatdistributioninaheatingsystem.Itconsistsofacasingwithan
internalcircuitboardandterminals.Thecoverplateofthecasingisremovable.
Electricshockdanger
Makesurebeforeopening,thatthewholeheatingsystemis
powereddown.
Note
Theheatingcontrollerisprotectedupto8Atotalcurrentconsumption.Eachoutputmaybeoccupiedwith2A.
Makesurethatthesevaluesarenotexceededbytheconnecteddevices.
1
BusconnectingterminalRS485AandB
5
Fuse8A(slow-acting)limitsthecurrent
consumptionoftheheatingcontroller.
2Addressswitch6
Lowvoltage–area(dangerousvoltage)
3
Slotforanoptionalpowersupply
(Thepowersupplyisneededwhentheburner
controlCMP06.2isused.Thepowersupply
takesoverthebussupply.)
7
Extralowvoltage(PELV)
4
Fuse6,3A(fast)forX31andX33
E1389EN2.0
OperatingmanualPelletronicTouch